TA13

Single Phase AMI Meter

Technical Specification
Meter Format Single phase two wires with neutral current measurement
Reference voltage 230V
Operating voltage 0.5Un ~ 1.3Un
Current 5A(basic current), 60A(maximum current)
Starting current 0.002Ib
Reference frequency 50Hz
Accuracy Class Class 1.0 (active), Class 2.0(reactive)
Clock Accuracy ±0.5s/day @ 23℃
Impulse generator energy constant 1000imp/kWh (1000imp/kvarh)
Operating temperature range Normal range: -25℃ ~ +45℃
Limited range: -40℃ ~ +55℃
Storage and transport temperature range -40℃ ~ +85℃
Relative humidity ≤97% (non-condensing)
Ingress Protection Rating IP54
Display(LCD) Main character dimensions 4.31mm(W)*8.0mm(H)
Energy display digits 8characters
Display mode Scrolling display, Push button
Data item OBIS
Battery Life Internal Lithium Battery > 5 years(blackout condition)
Communication interface Optical (IR), RS485, RS232, PLC, RF and Cellular.
Disconnect Relay 1P2W, 2 relays
Physical Dimensions Appr. 270mm(L)*134.5mm(W)*84.2mm(H)
Terminal Hole Diameter 9x9mm
Weight Appr. 1.65kg